GE Logiq S8 R4 XDclear Ultrasound w/ Linear and Curve Probes and Cart.
Fully refurbished, serviced, and ready to be used.
Abdominal, cardiac, OB/GYN, vascular, and musculoskeletal applications, along with advanced imaging options included.
Two units available:
Option 1: GE Logiq S8 R4 Ultrasound (2017)
XDclear
Monitor screenburn
Sw Ver R4
SW Revision 2.0
Probes:
ML6-15
Transducer Type: Wideband Matrix / Active-Matrix Linear Array
A wideband active-matrix linear array ultrasound transducer with a frequency range of 4.0 MHz to 15.0 MHz
High-resolution breast, musculoskeletal (MSK), vascular (peripheral vascular), small parts/organs, pediatrics, and neonatal imaging.
9L-D
Frequency range of 3-8 MHz
Transducer Type: Wideband Linear Array Ultrasound Probe.
Vascular, Small Parts, Pediatrics, and Abdominal examinations.
C1-6-
XDclear transducer technology
Transducer Type: broad-spectrum curved array
Frequency Range: 1 to 6 MHz
Applications: Abdominal and renal imaging, Obstetrics and gynecology (OB-GYN), Peripheral vascular, Urology and fetal heart, Tissue biopsy (supports multi-angle disposable guides).
Option 2: GE Logiq S8 R4 Ultrasound (2017)
XDclear
Monitor screenburn
Probes:
ML6-15
Transducer Type: Wideband Matrix / Active-Matrix Linear Array
A wideband active-matrix linear array ultrasound transducer with a frequency range of 4.0 MHz to 15.0 MHz
High-resolution breast, musculoskeletal (MSK), vascular (peripheral vascular), small parts/organs, pediatrics, and neonatal imaging.
9L
Transducer Type: Linear Array Transducer
Frequency range of 2.5 MHz. - 8.0 MHz
Vascular, Pediatrics, Small Parts.
C1-6- XDclear transducer technology
Transducer Type: broad-spectrum curved array
Frequency Range: 1 to 6 MHz
Applications: Abdominal and renal imaging, Obstetrics and gynecology (OB-GYN), Peripheral vascular, Urology and fetal heart, Tissue biopsy (supports multi-angle disposable guides).
Features:
-
XDclear™ transducer technology — designed to provide strong image quality, penetration, and resolution across a broad range of examinations.
-
Versatile shared-service platform — suitable for multiple departments and specialties rather than being limited to one application.
-
Advanced vascular imaging with B-Flow™ and B-Flow Color, Auto-IMT and flow-analysis capabilities.
-
Musculoskeletal imaging with advanced tools including B-Steer+, elastography and high-frequency linear transducers.
-
Cardiac imaging options including AutoEF, stress echo, strain imaging, tissue velocity imaging and anatomical M-Mode.
-
Shear Wave Elastography for quantitative assessment of tissue stiffness.
-
Strain Elastography for additional tissue characterization.
-
Volume Navigation / Fusion Imaging can combine real-time ultrasound with previously acquired CT, MR and other imaging datasets for image-guided procedures.
-
GE Raw Data allows additional image processing after acquisition.
-
Scan Assistant helps standardize exams and reduce repetitive operator inputs.
-
Portable cart design makes it practical for moving between rooms and departments. GE describes the S8 as having an ergonomic, portable design
Technical Specifications
| Specification |
GE LOGIQ S8 R4 |
| Manufacturer |
GE Healthcare |
| Model |
LOGIQ S8 |
| Revision |
R4 |
| Generation |
2017 |
| Technology |
XDclear™ |
| System Type |
Cart-based ultrasound |
| Monitor |
23" LCD on R4 systems |
| Active Probe Ports |
4 active ports + 1 parking port |
| Applications |
Abdominal, OB/GYN, cardiac, vascular, MSK, pediatric, urology, superficial/interventional |
| Imaging |
2D/B-Mode, Color Doppler, Power Doppler, B-Flow |
| Elastography |
Strain Elastography; Shear Wave Elastography depending on configuration |
| 3D/4D |
Available depending on configuration/probe |
| Volume Imaging |
Multiplanar, TUI, VCI, STIC, volume rendering |
| Fusion Imaging |
Available with Volume Navigation options |
| Needle Guidance |
B-Steer+; advanced tracking options available |
| Data |
GE Raw Data |
| Workflow |
Scan Assistant, Compare Assistant, automated optimization tools |
| Probes |
Wide selection of XDclear probes depending on configuration |